Home Print this page Email this page Users Online: 169
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2015  |  Volume : 3  |  Issue : 2  |  Page : 129-133

Comparison of rate of retraction and anchorage loss using nickel titanium closed coil springs and elastomeric chain during the en-masse retraction: A clinical study


Department of Orthodontics, CSMSS Dental College and Hospital, Aurangabad, Maharashtra, India

Correspondence Address:
Charushila Vinay Chaudhari
Department of Orthodontics, CSMSS Dental College and Hospital, Aurangabad, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2321-3825.150582

Rights and Permissions

Introduction: The aim of this study was to compare the clinical effectiveness of nickel titanium (NiTi) closed coil spring and elastomeric chain on rate of space closure in terms of anterior retraction and anchor loss. Materials and Methods: A total of 40 patients with first premolar extraction were randomly divided into two groups for space closure. Group 1 consisted of 20 patients in whom space closure was done with NiTi closed coil springs whereas in group 2 consisted of 20 patients with elastomeric chain. The amount of anterior retraction, anchor loss and rate of space closure was measured before start of retraction and at end of 4 months clinically and radiographically. Results: The observations obtained in the study were subjected to statistical analysis, so as to get their interpretation. All qualitative variables were compared using Fisher exact test. All quantitative variables were described using mean ± standard deviation and compared using unpaired t-test. P < 0.05 was considered as significant. The unpaired t-test, when applied, revealed there was a faster rate of space closure by NiTi closed coil springs when compared with elastomeric chain. Furthermore, anchor loss was more with NiTi springs as compared with elastomeric chain. Conclusion: The results of this study demonstrated faster space closure (with anterior retraction) along with significant anchorage loss was achieved by using NiTi closed coil springs when compared to the elastomeric chain.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2326    
    Printed39    
    Emailed1    
    PDF Downloaded592    
    Comments [Add]    
    Cited by others 1    

Recommend this journal