Year : 2016  |  Volume : 4  |  Issue : 1  |  Page : 18-23

Comparison of elemental composition and morphological characteristics of orthodontic titanium mini-implants


1 Department of Orthodontics, Al-Badar Dental College and Hospital, Gulbarga, India
2 Department of Orthodontics, Al-Badar Rural Dental College and Hospital, Gulbarga, India
3 Department of Orthodontics, PMNM Dental College and Hospital, Bagalkot, Karnataka, India

Correspondence Address:
Avinash Kumar
Reader, Department of Orthodontics, Al-Badar Dental College and Hospital, Gulbarga, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2321-3825.179740

Rights and Permissions

Objectives: To evaluate and compare the indigenous and imported titanium mini-implants for their elemental composition and morphological characteristics. Materials and Methods: Five indigenous titanium mini-implants of (SK Surgical, Pune, Maharashtra, India) and five imported titanium mini-implant samples (IMTEC Corp., Ardmore, OK, USA) having a length of 8 mm each was compared. Elemental analysis was done by energy dispersive spectroscopy. Morphological characteristics such as the external diameter, internal diameter, thread interval or pitch, cutting edge of the threads, the shape of the screw and length were evaluated by scanning electron microscopy. Data were analyzed by one-way ANOVA to evaluate the differences in samples of the same group, and Student's t-test was used to compare the morphological characteristics between the two groups. Results: The elemental analysis showed that the indigenous mini-implants correspond to alpha-phase titanium alloy compared to imported mini-implants which correspond to alpha + beta phase titanium alloy. Statistical tests showed that the imported mini-implants were tapered compared to indigenous mini-implants which were straight or cylindrical in shape. There was a statistically significant difference in other morphological characteristics of mini-implants between the two groups as well. Conclusion: Indigenous mini-implants tested were made of titanium alloy (Ti-4Al) and imported mini-implants were made of titanium alloy (Ti-6Al-4V). Significant mean differences were found in the morphological characteristics amongst the indigenous titanium mini-implants (F > 2.49).


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed805    
    Printed52    
    Emailed0    
    PDF Downloaded296    
    Comments [Add]    

Recommend this journal