SURGICAL TECHNIQUE |
|
Year : 2012 | Volume
: 4
| Issue : 1 | Page : 15-18 |
|
Radiation-free insertion of distal interlocking screw in tibial and femur nailing: A simple technique
Ritesh Kumar Soni1, Surender Mohan Mehta1, Bhanu Awasthi1, Janith Lal Singh2, Amit Kumar3, Lokesh Thakur1, Sujit Kumar Tripathy2
1 Department of Orthopaedics, Dr. Rajender Prasad Government Medical College (RPGMC), Tanda, Kangra, India 2 Department of Orthopaedics, Postgraduate Institute of Medical Education and Research (PGIMER), Chandigarh, India 3 Department of Orthopaedics, Government Medical College, Chandigarh, India
Correspondence Address:
Ritesh Kumar Soni Senior Resident, Department Of Orthopedics, Dr. RPGMC, Tanda, Kangra, H.P. - 176 001 India
Source of Support: None, Conflict of Interest: None | 2 |
DOI: 10.4103/2006-8808.100346
|
|
Background: Distal interlocking screw insertion in intramedullary nailing of long-bone fracture is a challenging task for orthopedic surgeons. It is difficult particularly when the surgeon is in his learning stage or when image intensifier is not available. We describe a radiation-free technique of distal interlocking screw insertion which is easy and practicable. Materials and Methods: In this technique, a same length nail is placed over the skin (outer nail) and through its distal-most screw hole, a 3.2 mm drill bit is inserted to drill the distal locking screw hole of the intramedullary nail (inner nail). With a small skin incision over the distal screw holes, the distal-most screw hole is identified; the bone window overlying the screw hole is widened with an awl and a locking bolt is inserted with a washer under direct visualization. The other distal interlocking screw is simply drilled by matching the other three holes of the outer and inner nails. We have operated 86 patients (39 femoral shaft fracture and 47 tibial shaft fracture) in 1 year where this technique was used. There were 41 open fracture and 45 closed fracture. Results: Within 6 months of follow-up, bony union was achieved in 36 of 39 femur fractures and 45 of 47 tibial fractures. No unwanted complications were observed during the postoperative period and in follow-up. Conclusion: This method of radiation-free distal interlocking screw insertion is simple and can be used in third world country where image intensifier facility is not available. However, surgeons are encouraged to use image intensifier facility where the facility is available. |
|
|
|
[FULL TEXT] [PDF]* |
|
|
|